Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Innovative design addressing complex airway stenosis: Multidimensional performance assessment of a novel Y-shaped airway stent

Tytuł:
Innovative design addressing complex airway stenosis: Multidimensional performance assessment of a novel Y-shaped airway stent
Autorzy:
Jiang, Yuyue
Shan, Qungang
Huang, Wei
Yang, Nannan
Zhuang, Yaping
Wu, Zhuozhuo
Wang, Lu
Wang, Zhongmin
Data publikacji:
2024
Słowa kluczowe:
airway stent
biomechanical test
finite element analysis
stent dróg oddechowych
test biomechaniczny
analiza elementów skończonych
Język:
angielski
Dostawca treści:
BazTech
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
“Y-shaped” airway stents have been widely used in the treatment of airway diseases, especially airway stenosis, due to their excellent flexibility. However, the current research on the flexibility of “Y-shaped” airway stents is still blank, limiting the possibility of improving the performance of stents in complex clinical disease. This study aimed to establish multi-dimensional evaluation of the flexibility of a novel segmented “Y-shaped” airway stent and two kinds of conventional stents. We evaluated the flexibility of the segmented stent, wholly knitted stent, and silicone stent by in vitro mechanical testing and finite element analysis methods. That is, the bending force and spring-back force of three kinds of stent were measured in left-right, anterior-posterior and longitudinal directions. The torque of the stents in torsion-recovery test of branches of stent was also executed. Finite element analysis was performed to evaluate the change of diameter. According to the detection, the bending force and spring-back force of the branch of the segmented stent during left-right and anterior-posterior compression, and the torque during torsion and recovery were lower than those of the other two stents. In finite element analysis, the diameter change of the segmented stent was minimal among the three stents. The flexibility of the segmented “Y-shaped” airway stent was better than that of the conventional “Y-shaped” airway stents, indicating that it has better adaptability and resistance to compression when implanted in the body.
Opracowanie rekordu ze środków MNiSW, umowa nr POPUL/SP/0154/2024/02 w ramach programu "Społeczna odpowiedzialność nauki II" - moduł: Popularyzacja nauki (2025).

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies