Estimating gaseous pollutants in the air near Daura Refinery, Daura Power Plant and South of Baghdad Power Plant by calculating the fuel discharge

Tytuł:
Estimating gaseous pollutants in the air near Daura Refinery, Daura Power Plant and South of Baghdad Power Plant by calculating the fuel discharge
Autorzy:
Roomi, Thaer O.
Abed, Adel S.
Data publikacji:
2021
Słowa kluczowe:
gaseous pollutants
SO2
CO
NO2
power plant
refinery
Język:
angielski
Dostawca treści:
BazTech
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie  Pełny tekst  Link otwiera się w nowym oknie
This study addresses estimation of emission rates and concentrations of SO2, CO and NO2 gases emitted from Daura Refinery (DR), Daura Power Plant (DPP) and South of Baghdad Power Plant (SBPP) by calculating the fuel discharge. The estimations were made by using the Gaussian plume model of dispersion at distances within 10 km from the pollution source for January, April, July and October 2017 under two stability conditions, slightly stable and moderately unstable. The effect of wind speed and direction as well as the ambient temperature of the surrounding air on the dispersion and transmission of air pollutants were also investigated. It was found that the unstable conditions are better for dispersing out atmospheric pollutants. The results showed that Zafarania District was the most affected by pollutants emitted from DR and BSPP while Daura District was more affected by DPP due to the prevailing wind direction. It was also found that an increase in wind speed leads to a decrease in the concentration of pollutants. The concentration of pollutants is inversely proportional to the height of the chimney, the speed of the gas leaving the chimney, while it is directly proportional to the diameter of the chimney. DPP has higher emission rates than DR and SBPP while at the surface level, the pollutants concentrations emitted from DR are greater than those emitted from DPP and SBPP.
Opracowanie rekordu ze środków MEiN, umowa nr SONP/SP/546092/2022 w ramach programu "Społeczna odpowiedzialność nauki" - moduł: Popularyzacja nauki i promocja sportu (2024)

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies