Simulation verification of damage detection algorythm
A modal filter is an excellent indicator of damage detection, with such advantages as low computational effort due to data reduction, ease of automation and low sensitivity to environmental changes [4,5]. However to apply it in a real SHM system, it first needs to be extensively tested to verify its sensitivity to damage location, inaccuracy of sensor location in the consecutive experiments, measurements noise as well as changes in ambient conditions, such as temperature and humidity. This paper presents the results of numerical simulations that test the sensitivity of the modal filter based damage detection method to the factors listed above. For this purpose three numerical models of the physical systems were created and applied.
Filtr modalny jest bardzo dobrym wskaźnikiem wykrywającym uszkodzenie, posiadającym takie zalety jak niewielkie wymagania obliczeniowe, łatwość automatyzacji procedury i niska wrażliwość na zmiany warunków zewnętrznych [4,5]. Jednakże, aby zastosować go w rzeczywistym układzie monitoringu musi najpierw przejść szczegółowe badania symulacyjne w celu weryfikacji jego wrażliwości na takie czynniki jak lokalizację uszkodzenia, niedokładność umieszczania czujników w kolejnych pomiarach, zakłócenia toru pomiarowego oraz zmiany warunków otoczenia takich jak temperatura i wilgotność. W pracy tej przedstawiono wyniki weryfikacji symulacyjnej, sprawdzającej wpływ powyższych czynników na wyniki filtracji modalnej. W tym celu sporządzone zostały i zastosowane trzy modele numeryczne.