In vitro analysis of urinary stone composition in dual-energy computed tomography

Tytuł:
In vitro analysis of urinary stone composition in dual-energy computed tomography
Autorzy:
Chrzan, Robert
Stępień, Monika
Gawlas, Wojciech
Data publikacji:
2018
Słowa kluczowe:
dual energy computed tomography
urinary stone
Język:
angielski
ISBN, ISSN:
1733134X
Prawa:
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Purpose: Dual energy computed tomography (DECT) is a new method of computed tomography (CT) imaging, allowing the assessment of not only the object's morphology, but also its composition. The aim of the study was to evaluate the potential of in vitro DECT evaluation of urinary stones' chemical composition. Material and methods: Six samples of surgically removed renal stones were scanned using DECT and analyzed by scanner vendor software. Uric acid stones were marked red and calcium stones white by the software. The real composition of the stones was finally verified using physicochemical laboratory analysis. Results: In 5 out of 6 samples, the composition of stones in DECT (3 samples identified as uric acid and 2 samples as calcium) was consistent with the physicochemical analysis (3 samples identified as uric acid, 1 as calcium phosphate, 1 as calcium oxalate). In DECT it was not possible to determine more precisely the type of calcium compounds (calcium phosphate vs. calcium oxalate) as established in the physicochemical analysis. In one stone identified in physicochemical analysis as uric acid, DECT detected a composite layered structure containing both uric acid and calcium compounds. Conclusions: DECT allows uric acid to be distinguished from calcium urinary tract stones, which is crucial in the choice of appropriate therapy. Using the available hardware and software, it was not possible to more accurately distinguish types of calcified stones. Evaluation of the stone type in DECT may be limited in the case of mixed chemical composition.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies