The advantages of a spine coil over a torso coil in magnetic resonance imaging examination of the sternoclavicular joints

Tytuł:
The advantages of a spine coil over a torso coil in magnetic resonance imaging examination of the sternoclavicular joints
Autorzy:
Kwapisz, Adam
Podgórski, Michał Tomasz
Grzelak, Piotr
Kusak, Artur Stefan
Data publikacji:
2018
Słowa kluczowe:
technique
torso coil
spine coil
sternoclavicular joints
MRI
protocol
Język:
angielski
ISBN, ISSN:
1733134X
Prawa:
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
http://creativecommons.org/licenses/by-nc-nd/4.0/legalcode.pl
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Purpose: There are two standard methods for an magnetic resonance imaging (MRI) examination of the sternoclavicular joints: with loop coils and the patient in the prone position, or with torso coils with the patient in a supine position. In some centres these joints are examined with the spine coil in a patient laying prone. There are no reports on the advantages of this method. Our hypothesis is that despite different MRI systems, application of a spine coil will improve examination quality. Material and methods: Twenty-one healthy volunteers (10 female, 11 male, mean age 25 years) were randomised into three groups and scanned using three different MRI scanners (1.5T: Siemens Avanto, Philips Ingenia, 3.0T: Philips Achieva). Each volunteer was examined twice: using a standard protocol with a torso coil and with a spine coil, in prone position. The two groups were compared with regard to the intensity of motion artefacts using the χ2 test, and to the signal-to-noise ratio with the Wilcoxon signed-rank test. Results: Application of a spine coil resulted in a significant decrease in the number of motion artefacts in all three planes (axial: p = 0.0004; sagittal: p < 0.0001; coronal: p = 0.0054). Moreover, the signal-to-noise ratio was significantly increased with the application of a spine coil (28.6 ± 8.6 vs. 18.5 ± 7.3, respectively; p = 0.0002). Conclusions: Application of a spine coil with the patient in a prone position is suitable for MRI evaluation of the sternoclavicular joints. It allows a higher signal-to-noise ratio and a lower intensity of motion artefacts to be obtained compared to a torso coil.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies