Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Investigation of silver nanoparticles embedded in extracted gelatins from camel, bovine, and fish bones for possible use in radiation dosimetry

Tytuł:
Investigation of silver nanoparticles embedded in extracted gelatins from camel, bovine, and fish bones for possible use in radiation dosimetry
Autorzy:
Alrashidi, Thaar K.
Aljuhani, Alwaleed
Almugaiteeb, Faisal
Badi, Nacer
Al-Aoh, Hatem A.
Alghamdi, Saleh A.
Alsharari, Abdulrhman M.
Alzahrani, Ahmed Obaid M.
Almalki, Khaled
Data publikacji:
2023
Słowa kluczowe:
bone
light absorption
mammals
metal nanoparticles
scanning electron microscopy
silver nanoparticles
Język:
angielski
Dostawca treści:
BazTech
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Gelatins from camel, bovine, and fish bones were successfully extracted by using chemical pretreatment and heating methods. The bones were demineralized for 3 days at ambient temperature using hydrochloric acid solutions (0.5–1 M), and the collagen was partially hydrolyzed by preheating in distilled water at 75–80°C for 3 h, followed by extraction temperature at 90°C for 1 h. Free-standing films of gelatin entrained with silver nanoparticles (Gel/AgNPs) at low concentrations (1.25, 2.5, and 5 mM) were synthesized as radiation dosimeters. A high-energy ultrasonic homogenizer was used to dissolve the gelatin in distilled water and to disperse the AgNPs in the gelatin. The nanocomposites’ morphology and crystallinity were investigated using scanning electron microscopy (SEM), optical absorption, and Fourier transform infrared (FTIR) spectroscopies. Dose enhancement was assessed using X-ray irradiations with beam energies below and above silver K-edge. The beam was configured by setting the X-ray generator at 15, 25.5, and 35 kV potential and a beam current of 1 mA. An X-ray detector is used to detect the number of electrons after passing through Gel/AgNPs samples. The use of AgNPs embedded in gelatin caused the enhancement of X-ray radiation absorption, and the highest percentage of linearity for the dosimeter was found to be 90% in the optical range of 395 nm to 425 nm. The preliminary results demonstrated that Gel/AgNPs material may be used in radiation dosimetry for low-energy radiotherapy sources.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies