Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Development and Validation of RP-HPLC Method for Simultaneous Estimation of Glibenclamide and Thymoquinone in Rat Plasma and Its Application to Pharmacokinetics

Tytuł:
Development and Validation of RP-HPLC Method for Simultaneous Estimation of Glibenclamide and Thymoquinone in Rat Plasma and Its Application to Pharmacokinetics
Autorzy:
Ahmad, A.
Khan, R. M. A.
Alkharfy, K. M.
Data publikacji:
2015
Słowa kluczowe:
glibenclamide
thymoquinone
simultaneous determination
RP-HPLC
pharmacokinetics
Język:
angielski
Dostawca treści:
BazTech
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
A rapid, accurate, and sensitive reverse phase high-performance liquid chromatographic method was developed and validated for the simultaneous determination and quantification of glibenclamide and thymoquinone in rat plasma in the presence of internal standard (thymol). Chromatograms were developed with methanol, acetonitrile, and buffer (50:20:30, v/v/v) solvent system on a Symmetry® C18 (5 μm, 3.9 × 150 mm) column, and pH was adjusted to 4.5 with orthophosphoric acid. Mobile phase was pumped at a flow rate of 1.5 mL min-1 with 254 nm ultraviolet (UV) detection. Validation of the method was performed in order to demonstrate its selectivity, linearity, precision, accuracy, limits of detection, and quantification (LOD and LOQ). Standard curves were linear (r2 = 0.996 and 0.999 for glibenclamide and thymoquinone) over the concentration range 0.5–50 μg Ml-1. The coefficient of variation (CV) of < 6% and accurate recovery of 87.54–105.19% for glibenclamide and CV of <5% and accurate recovery of 86.08–103.19% for thymoquinone were found to be in the selected concentration range of 0.5–50 μg Ml-1. The lower limits of detection and quantitation of the method were 0.109 and 0.332 μg Ml-1 for glibenclamide and 0.119 and 0.361 μg Ml-1 for thymoquinone, respectively. The within and between-day coefficients of variation were less than 7%. The validated method has been successfully applied to measure the plasma concentrations in a drug interaction study of glibenclamide with thymoquinone in an animal model to illustrate the scope and application of the method.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies