Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Non-invasive analysis of the bioelectrical impedance of a human forearm

Tytuł:
Non-invasive analysis of the bioelectrical impedance of a human forearm
Autorzy:
Plonis, Darius
Kalinauskas, Edas
Katkevičius, Andrius
Krukonis, Audrius
Data publikacji:
2024
Słowa kluczowe:
non-invasive
bioimpedance
digital signal processing
human tissues
Język:
angielski
Dostawca treści:
BazTech
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie  Pełny tekst  Link otwiera się w nowym oknie
This study explores the practical application and impact of bioimpedance analysis in mobile devices for monitoring human health. The objective of the study is to propose a feasible application of non-invasive bioimpedance analysis by using the tetrapolar electrode connection method and the Cole–Cole model. Bioimpedance measurements and the calculation of electrical parameters are performed using ANSYS HFSS software for theoretical calculations and digital signal processing technology for real-time measurements using hardware devices. The study focuses on a model of the front arm, including tissues such as bone, fat, muscles, arteries and skin, with glucose concentrations as test cases. The simulated characteristic impedance with the ANSYS HFSS software package at 125 kHz varied from 315.8 Ω to 312.6 Ω, and the measured forearm characteristic impedance with hardware varied from 150.1 Ω to 151.3 Ω. The measured characteristic impedance when the heart is in systole and diastole also differed, with a difference of about 0.85% of the maximum impedance measured. The study demonstrates the potential of non-invasive bioimpedance analysis to address health issues such as obesity and heart disease. It also highlights its usefulness as a non-invasive alternative for measuring glucose concentration in diabetic patients to reduce the risk of infection. The findings indicate the feasibility of using bioimpedance analysis in mobile devices for health monitoring purposes.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies