Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Simultaneous quantification of related substances of ezetimibe and simvastatin in combined dosage form using a novel stability-indicating liquid chromatographic method

Tytuł:
Simultaneous quantification of related substances of ezetimibe and simvastatin in combined dosage form using a novel stability-indicating liquid chromatographic method
Autorzy:
Desai, P. R.
Mehta, P. J.
Ojha, S. K.
Chokshi, A. B.
Data publikacji:
2018
Słowa kluczowe:
Ezetimibe
simvastatin
high-performance liquid chromatography
impurity
method validation
Język:
angielski
Dostawca treści:
BazTech
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
A novel, simple, robust, and rapid reversed-phased high-performance liquid chromatographic method has been developed for the separation and quantitative determination of the related substances of ezetimibe and simvastatin in combined dosage forms. Successful separation of the drug from the process-related impurities and degradation products formed under stress conditions was achieved on Inertsil ODS-3V (150 × 4.6 mm, 5.0 μm) column. The gradient liquid chromatography (LC) method employs solution A and solution B as mobile phase. The solution A contains 0.1% orthophosphoric acid solution in water, and solution B contains 0.1% orthophosphoric acid solution in acetonitrile. Flow rate was monitored at 2.0 mL/min, and the ultraviolet (UV) detection, at 238 nm. In forced degradation studies, the effect of acid, base, oxidation, UV light, and temperature was investigated, showing that good resolution between the peaks corresponds to process-related impurities and degradation products from both analyte. The performance of the method was validated according to the present International Conference on Harmonization (ICH) guidelines for specificity, limit of detection, limit of quantification, linearity, accuracy, precision, ruggedness, and robustness. To the best of our knowledge, a rapid LC method, which separates all the impurities of ezetimibe and simvastatin in combined dosage forms, disclosed in this investigation was not published elsewhere.
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2018).

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies