Tytuł pozycji:
Agomelatine release from DLP 3D-printed rocket microneedle systems containing a 3% AGM-drug resin mixture
- Tytuł:
-
Agomelatine release from DLP 3D-printed rocket microneedle systems containing a 3% AGM-drug resin mixture
- Autorzy:
-
Kordyl, Oliwia
Wojtyłko, Monika
Osmałek, Tomasz
Budnik, Irena
Froelich, Anna
Kuczko, Wiesław
Wichniarek, Radosław
Tomczak, Dorota
- Współwytwórcy:
-
Kordyl, Oliwia
- Data publikacji:
-
2025-03-24
- Wydawca:
-
RepOD
- Tematy:
-
Medicine, Health and Life Sciences
agomelatine
3D printing
drug release
microneedle systems
transdermal drug delivery
franz cells
HPLC
- Dostawca treści:
-
Repozytorium Otwartych Danych
-
Przejdź do źródła  Link otwiera się w nowym oknie
Raw data from release studies of agomelatine (AGM) from microneedle systems.
Microneedle system specifications:
- 3D printing method: Digital Light Processing (DLP)
- microneedle shape: Rocket
- coating-gel type: - (no coating) 3% AGM mix within resin (served as printing material)
Drug release studies: The permeation of agomelatine (AGM) was evaluated using Franz Diffusion Cells (Teledyne Hanson 376 Research, USA) without using any membrane.
Quantification of AGM: The amount of AGM permeated was analyzed using High-Performance Liquid Chromatography (HPLC) (Shimadzu Nexera-I LC-2040C, Japan) with LabSolution Lite software.
- Chromatographic Conditions:Column: Reversed-phase C18 (HyperClone BDS C18, 5 µm, 4.6 × 250 mm, Phenomenex, Torrance, CA, USA)
- Column Temperature: 30.0 ± 0.2°C
- Mobile Phase: Acetonitrile and 0.05 M potassium dihydrogen phosphate solution (pH = 2.9, adjusted with 85% orthophosphoric acid) in a 35:65 ratio
- Mode: Isocratic
- Flow Rate: 1.0 mL/min
- Detection Wavelength: 230 nm
The set contains data in LCD/ LCB format, created using the LabSolutions software (HPLC, Nexera LC 2040C). Data file (.lcd) contains all analysis results and acquisition information from the following files. Data in .txt format can be read without the need for LabSolutions software.