Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

The use of a novel type of distal protection system (FiberNet®) in the ercutaneous management of saphenous vein graft disease

Tytuł:
The use of a novel type of distal protection system (FiberNet®) in the ercutaneous management of saphenous vein graft disease
Zastosowanie nowego systemu protekcji dystalnej (FiberNet®) podczas angioplastyki pomostów żylnych
Autorzy:
Laskowicz, Bartosz
Musiałek, Piotr
Odrowąż-Pieniążek, Piotr
Podolec, Piotr
Dzierwa, Karolina
Paluszek, Piotr
Hlawaty, Marta
Tekieli, Łukasz
Żmudka, Krzysztof
Data publikacji:
2010
Słowa kluczowe:
mesh-covered stent
embolic protection devices
saphenous vein graft disease
Język:
angielski
Prawa:
http://creativecommons.org/licenses/by-nc-nd/4.0/pl/legalcode
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 4.0 Międzynarodowa
Linki:
https://www.mp.pl/kardiologiapolska/en/node/9743/pdf  Link otwiera się w nowym oknie
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Percutaneous intervention in saphenous vein grafts is associated with a high risk of distal embolisation by plaque material, ‘no flow’ phenomenon and clinical complications such as myocardial infarction or death. According to randomised trial evidence, intervention in a degenerated vein graft should be performed using an embolic protection device (EPD), since this strategy significantly reduces periprocedural and 30 day adverse event rate. FiberNet® is a novel distal protection system with unique characteristics of a low crossing profile (0.031’’ for vessel size 3.5–5 mm), ‘cotton wool’-like three dimensional design and a small pore size (40 µm). The FiberNet® does not require a separate delivery sheath and self-achieves its optimal apposition to the vessel wall; the EPD system also contains a dedicated aspiration catheter. We present the use of FiberNet® in a 77 year-old patient who had undergone coronary artery bypass grafting 20 years ago and currently presented with CCS class III angina due to a significant stenosis of the saphenous vein graft to the marginal branch. The procedure involved the use of a novel mesh-covered stent (MGuard®) designed to ‘trap’ the plaque material between the stent and the vessel wall. It was technically successful and clinically uncomplicated, and the patient remains well six months later.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies