Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Validation of the Polish-language version of the COPD Assessment Test

Tytuł:
Validation of the Polish-language version of the COPD Assessment Test
Autorzy:
Kuziemski, Krzysztof
Czajkowska.Malinowska, Ma.gorzata
Farnik, Małgorzata
Połtyn, Beata
Trzaska.Sobczak, Marzena
Kania, Aleksander
Miszczuk, Marta
Brożek, Grzegorz
Krenke, Rafał
Celejewska-Wójcik, Natalia
Barczyk, Adam
Data publikacji:
2019
Słowa kluczowe:
reproducibility
chronic obstructive pulmonary disease
CAT
reliability
validation
Język:
angielski
ISBN, ISSN:
00323772
Prawa:
http://creativecommons.org/licenses/by-nc-sa/4.0/legalcode.pl
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Na tych samych warunkach 4.0 Międzynarodowa
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
INTRODUCTION The COPD Assessment Test (CAT) is a standardized patient–completed tool dedicated to assessment of symptom severity. While the Polish CAT version has been used for a few years, it has not been validated so far. OBJECTIVES The aim of the study was to validate the Polish‑language version of the CAT questionnaire by assessing its reproducibility and reliability. PATIENTS AND METHODS Validation of the Polish‑language version of the CAT questionnaire was a substudy of the international multicenter observational cross‑sectional POPE survey of patients with chronic obstructive pulmonary disease (COPD) in Central and Eastern European countries. The study was completed in 395 outpatients with stable disease at least 4 weeks before the survey. Validation was performed with the use of the Spearman correlation and Cronbach α coefficients, Cohen κ test, and the Bland–Altman procedure. RESULTS The internal consistency assessed by the Cronbach α coefficient was 0.87 for the questionnaire and 0.84 to 0.86 for its separate items. The repeatability of the questionnaire was good to very good (Cohen κ, 0.76–0.85; P <0.01). The Spearman coefficient for the sum of scores of test–retest responses was 0.95 (P <0.01). The Bland–Altman analysis revealed very good test–retest and interrater reliability, with the mean difference between test I and test II results of –0.556 (95% CI, –0.345 to 0.767). CONCLUSIONS The Polish version of the CAT questionnaire is a reproducible and reliable instrument for evaluation of patients with COPD and should be recommended for use in clinical practice.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies