Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Development of SPE/HPLC-DAD to determine residues of selected disinfectant agents in surface water

Tytuł:
Development of SPE/HPLC-DAD to determine residues of selected disinfectant agents in surface water
Autorzy:
Baranowska I.
Wojciechowska I.
Język:
angielski
Dostawca treści:
AGRO
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
The aim of our research was to develop a chromatographic method for simultaneous determination of five substances used as disinfectant agents. Biphenyl-2-ol (BPh), chloramine T (ChT), 4-chloro-3-methylphenol (4C3MPh), triclosan (TCS), and triclocarban (TCC) were determined using high-performance liquid chromatography. Chromatographic analyses were carried out on a Develosil RP Aqueous AR-5 RP-30 column (250 mm × 4.6 mm, 5.0 μm particles) with gradient elution of mobile phase including methanol and water, and with a DAD detector. Satisfactory resolution of the determined substances was obtained in 10 minutes. The linearity ranges of the calibration curves (in matrix) of examined disinfectants ranged from 0.10 to 10.00 μg·mL⁻¹ for ChT, 4C3MPh and TCC, and from 0.25 to 10.00 μg·mL⁻¹ for BPh and TCS. The developed method was applied to determine of mentioned compounds in water samples. Water samples were prepared for chromatography analyses by using C18 solid phase extraction discs. The recoveries of analyzed substances ranged from 82 to 101% (except for Chloramine T, which is unstable in water medium). Analyses were operated after extraction of analytes from 3 L of real water samples. The method detection limits in samples of water were: 1.6 ng·mL⁻¹ for BPh, 0.6 ng·mL⁻¹ for ChT, 1.4 ng·mL⁻¹ for 4C3MPh, 1.9 ng·mL⁻¹ for TCS, and 1.0 ng·mL⁻¹ for TCC. This method was successfully applied to analyze examined disinfectants in surface water samples collected from rivers and wastewater in Poland. Four of five compounds were detected in the tested samples in the concentration ranging from 5.05 to 30.36 μg·L⁻¹.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies