Transparent laser damage resistant nematic liquid crystal cell “LCNP3”

There exists the problem in diagnostics of dense plasma (so-called Thomson diagnostics). For this purpose the plasma is illuminated by series of high energy laser pulses. The energy of each separate pulse is as large as 3 J, so it is impossible to generate a burst of such pulses by a single laser. In this situation, the pulses are generated by several independent lasers operating sequentially, and these pulses are to be directed along the same optical path. To form an optical path with ʎ = 1.064 μm and absolute value of the laser pulse energy of 3 J, a special refractive index matched twisted Nematic Liquid Crystal Cell of type LCNP3, with switching on time ƮON smaller than 3 μs was applied.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies