Simulations and techno-economic analysis of solar cooling system

Tytuł:
Simulations and techno-economic analysis of solar cooling system
Autorzy:
Kalina, Jacek
Rabiej, Michał
Santos Silva, Carlos
Data publikacji:
2024
Słowa kluczowe:
solar cooling
building simulation
absorption chillers
solar thermal collector
thermal energy storage
Język:
angielski
Dostawca treści:
BazTech
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie  Pełny tekst  Link otwiera się w nowym oknie
In this paper, a solar absorption cooling system with a chilled water storage tank and peak load compression system was considered for cooling the Instituto Superior Tecnico Tower building in Lisbon, Portugal. To fulfill this task, a dynamic simulation of the building was performed using the DesignBuilder software, then a solar collector field was designed. The next step was to build a computational model of the absorption chiller in the Engineering Equation Solver software, which allowed for further simulation of the annual operation of the system supported by the chilled water tank and the backup system with compressed air conditioning. The last stage of the work was the economic analysis of such a system in comparison with conventional compressed air conditioning. The simulation results and economic analysis showed that the solar absorption cooling system could be a beneficial cooling solution for the Instituto Superior Tecnico Tower building. However, it would have to operate with an energy storage system and a peak load compression backup system to be able to cool the building efficiently all year round. Additionally, such a solution could have a significant positive impact on climate through considerable annual savings in electricity consumption. Results revealed that the proposed system meets the cooling demand of the building, mainly by solar-energy-driven absorption chiller. The annual contribution of a backup compression chiller ranges from 20% to 36% depending on the size of chilled water storage tanks. Financial calculations revealed discounted payback periods in the range of 4.5 to 12.5 years depending on the system configuration.
Opracowanie rekordu ze środków MNiSW, umowa nr POPUL/SP/0154/2024/02 w ramach programu "Społeczna odpowiedzialność nauki II" - moduł: Popularyzacja nauki (2025).

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies