A novel ultra-low-frequency micro-vibration calibration method based on virtual pendulum motion trajectories of the Stewart platform

Tytuł:
A novel ultra-low-frequency micro-vibration calibration method based on virtual pendulum motion trajectories of the Stewart platform
Autorzy:
Ye, Tong
Liu, Zhihua
Cai, Chenguang
Bao, Fubing
Xu, Fei
Lian, Xiangkun
Data publikacji:
2024
Słowa kluczowe:
micro-vibration calibration
Stewart platform
ultra-low frequency
virtual pendulum motion trajectories
Język:
angielski
Dostawca treści:
BazTech
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie  Pełny tekst  Link otwiera się w nowym oknie
Micro-acceleration generation during ultra-low-frequency micro-vibration calibration is a sensitive issue. There are issues of traditional pendulum tables being unable to change the pendulum radius and direction to produce micro-accelerations of different magnitudes, and the line shakers having a low signal-to-noise ratio when the vibration amplitude is the same as that of the pendulum tables. Therefore, a novel ultra-low-frequency micro-vibration calibration method is proposed to solve the above issues based on virtual pendulum motion trajectories of the Stewart platform. The micro-accelerations of 10-5 to 10-3 m/s2 can be generated by the trajectories with the radius of up to 12 m, the displacement amplitudes of up to 11.636 mm and the frequencies between 0.01 and 0.1 Hz. In the virtual pendulum motion, the maximum acceleration can be 2481 times greater than the acceleration of linear motion at the same frequency and displacement amplitude. In a comparison experiment with the current rotating platform, the maximum relative deviation of sensitivity amplitude calibration for pendulum motion around the x- and y-axis based on the Stewart platform are 0.411% and 0.295% respectively. The above results demonstrate the validity and reliability of this kind of method.
This work was supported by National Natural Science Foundation of China (No. 52075512) and the Fundamental Research Funds for the National Institute of Metrology of China (No. AKYZD2302).

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies