Tytuł pozycji:

Rapid, sensitive, and validated HPLC method for analysis of metronidazole and tinidazole under identical chromatographic conditions with UV detection and liquid-liquid extraction: application in bioequivalence studies

Tytuł:
Rapid, sensitive, and validated HPLC method for analysis of metronidazole and tinidazole under identical chromatographic conditions with UV detection and liquid-liquid extraction: application in bioequivalence studies
Autorzy:
Emami, J.
Rezazadeh, M.
Data publikacji:
2013
Słowa kluczowe:
metronidazole
tinidazole
HPLC
pharmacokinetics
bioavailability
Język:
angielski
Dostawca treści:
BazTech
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
A simple, rapid, and sensitive reversed-phase HPLC method was developed and validated for determination of metronidazole and tinidazole in human plasma samples under identical chromatographic conditions. This method involves liquid-liquid extraction using chloroform: isopropylalcohol (95:5). Chromatographic separation was performed using a μ-bondapack C18 (250 mm × 4.6 mm) column. The mobile phase consisted of potassium dihydrogen phosphate solution (0.005 M)/acetonitrile (80/20 v/v). The final pH of the mobile phase was adjusted to 4 ± 0.1 with orthophosphoric acid. The calibration curves were linear over the concentration range 0.1–15 μg/mL for metronidazole and tinidazole with the detection limit of 30 ng/mL. Within- and between-day precision and accuracy did not exceed 9.83% and 10.48%, respectively. Metronidazole and tinidazole were found to be stable in plasma samples with no evidence of degradation during 3 freeze-thaw cycles and 3 months storage in −70 °C. The current validated bio-analytical method was finally applied in bioequivalence studies of two different metronidazole and tinidazole products according to a standard two-way cross-over design with a two-week washout period. No statistically significant difference was observed between the logarithmically transformed AUC0-∞ and Cmax values. Therefore, generic products were considered bioequivalent with those of standards which could be used interchangeably.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies