Tytuł pozycji:
Thermal utilization of oak logs in a heating boiler working with low thermal output
Thermal utilization of oak waste wood was investigated in a 25 kW heat power domestic heating boiler. The boiler was connected to the water heat storage with the help of mixing and piping device. The investigated boiler was the uncontrolled one, which means that air combustion stream was regulated manually. Thermal utilization ought to be performed in a boiler in two steps: pyrolisis and wood gas combustion, but in case of low thermal output thermal utilization transforms into grate combustion. Sometimes the temperature in the pyrolisis region was higher than the temperature in the combustion area and thermal utilization took form of unsatisfactory grate combustion.
Badano termiczną utylizację polan dębowych w domowym grzewczym kotle o mocy 25 kW. Kocioł był połączony z zasobnikiem ciepła za pomocą modułu mieszająco-pompowego. Badany kocioł nie był sterowany automatycznie, to znaczy strumień powietrza do spalania był regulowany ręcznie za pomocą elektronicznego regulatora zmieniającego obroty wentylatora, na podstawie obserwacji wartości temperatury i koloru płomienia w komorze spalania, a także stężeń tlenu, tlenku węgla i tlenków azotu w spalinach w kominie. Kocioł był rozgrzany przed pomiarami, lecz w czasie badań pracował z małą wydajnością cieplną, średnio 5,8 kW. Termiczna utylizacja powinna zachodzić w tym kotle w dwóch stadiach: piroliza i spalanie gazu drzewnego, lecz w przypadku małej wydajności cieplnej czasem temperatura w strefie zgazowania była wyższa niż w strefie spalania. Spalanie przybierało formę nieodpowiedniego spalania rusztowego.