Mokre odpylanie przy użyciu zawiesiny o zmiennym stężeniu
The general characteristics of efficiency versus slurry mass concentration for the two test dusts with different physical properties were established. The critical concentration has been evalued above which the efficiency of dust collection decreasing. The general decrease of the dust collection efficiency is produced by the smaller efficiency for fine particles. It is presented on fractional efficiency characteristics for different concentrations in the slurry. Laboratory position was extended for the component which allows to identify isolated dust removal mechanisms.