A stopped-flow method for the determination of 6-methyl-2-thiouracil and 6-propyl-2-thiouracil applying induced iodine-azide reaction has been developed. Spectrophoto-metric detection at 596 nm was applied to monitor the decrease in the absorbance of iodine--starch complex within 10 s. The rate of the absorbance decrease was related to the concentration of thiouracil. Linear calibration range depended on the concentration of iodine and sodium azide in the iodine-azide solution, as well as on the considered analytical signals. Under the optimum reaction conditions both thiouracils could be determined at the concentration ranging from 0.2 ppm to 3 ppm (1.4-21 μmol L-1 and 1.2-17 μmol-1L-1 for 6-methyland 6-propyl-2-thiouracil. respectively). Relative standard deviation was below 1%. The developed method was applied to the determination of both compounds in drugs.
Opracowano metodę oznaczania 6-metylo-2-tiouracylu i 6-propylo-2-tiouracy!u w zatrzymanym przepływie z wykorzystaniem indukowanej reakcji jodo-azydkowej. Rejestrowano spadek absorbancji kompleksu jodo-skrobiowego w czasie 10 s. Szybkość spadku absor-bancji zależała od stężenia oznaczanego tiouracylu. Zakres liniowej zmienności mierzonego sygnału analitycznego dla badanych związków zależał od stężenia reagentów w roztworze jodo-azydkowym oraz od uwzględnianego sygnału analitycznego. W optymalnych warunkach eksperymentalnych oba tiouracyle można oznaczać w zakresie od 0,2 ppm do 3 ppm (1,4-21 μmol L-1 dla 6-metylo- i 1,2-17 μmol-1 dla 6-propylo-2-tiouracylu). Względne odchylenie standardowe było poniżej l%. Metodę zastosowano do oznaczania obu związków w lekach.