Wpływ niesymetrii zasilania na problem wykrywania zwarć zwojowych w silniku indukcyjnym
In this paper impact of supply anomalies on the machine diagnosis is presented. Diagnosis in sense at stator winding fault in case of turn to turn fault. The results of experimental in the case of physical modelling of stator short-circuits at different voltage asymmetry degree are presented. Damage of a stator winding was modelled by changing number of shorted turns in each phase. Supply voltage unbalance was modelled by increasing resistance in each motor phase. Analysis of symmetrical components of stator voltage and current was applied to investigation the asymmetry impact on shorted turns detection. Tests have been performed for the direct net supply at different load torques.