Tytuł pozycji:
Water treatment using hybrid method of coagulation and low-pressure membrane filtration
The paper presents the results of water treatment investigation, using UF/MF and a hybrid process coagulation-UF/MF. The experiments were conducted using capillary modules made of polyethersulfone (PES) for ultrafiltration and of polypropylene (PP) for microfiltration. Two coagulants, i.e. iron chloride (FeCl3ź6H2O) and aluminum sulfate (Al2(SO4)3ź18H2O), were used during the coagulation. The hybrid water treatment process was carried out in coagulation-sedimentation-MF/UF and "in-line" coagulation (without sedimentation)-MF/UF systems. Unlike a direct UF/MF, the hybrid processes allow an improvement in water quality and reduction in fouling intensity. UF efficiency can be predicted employing relaxation and resistance models. The mechanism of fouling based on Hermia's equation was determined.
Przedstawiono wyniki uzdatniania wody metodami bezpośredniej UF/MF oraz metodą hybrydową koagulacja-UF/MF. Badania prowadzono z wykorzystaniem kapilarnych modułów ultrafiltracyjnych z polieterosulfonu (PES) oraz modułów mikrofiltracyjnych z polipropylenu (PP). Zastosowano dwa rodzaje koagulantów: chlorek żelaza (FeCl3*6H2O) oraz siarczan glinu (Al2(SO4)3*18H2O). Proces hybrydowy prowadzono w układach koagulacja klasyczna-UF/MF oraz w układzie koagulacja in-line (bez sedymentacji)-UF/MF. Stwierdzono poprawę jakości wody oraz mniejszą intensywność foulingu w procesach hybrydowych w porównaniu z bezpośrednią UF i MF. Wydajność UF modelowano, opierając się na modelu relaksacyjnym oraz na modelu oporów filtracji. Wykorzystując model Hermii, określono mechanizm foulingu.