Tytuł pozycji:
A study of the effects of the sensor guideway slope on the results of the reference measurement of cylindricity deviations
The concept of applying the reference method to measure cylindricty deviations under industrial conditions, even on a machine tool, was developed at the Kielce University of Technology. The results of the statistical analysis show that the maximum error of the new method in relation to the radial method characterized by high accuracy is 19% for a level of confidence of 0.95. From the analysis and the experimental verification it is clear that the accuracy of the reference method can be considerably improved but it is necessary to study the potential sources of the method errors. One of the main factors to be analyzed is the sensor guideway slope.
Koncepcja pomiaru odchyłek walcowości metodą odniesieniową, opracowana w Politechnice Świętokrzyskiej, umożliwia pomiar elementów w warunkach przemysłowych, w tym na obrabiarce. Przeprowadzone badania statystyczne pokazaly, że maksymalny nowej metody w stosunku do dokładnej metody promieniowej wynosi ok. 19% dla poziomu ufności P = 0,95. Analiza nowej metody oraz wyniki uzyskane podczas eksperymentów pozwolily na stwierdzenie, że jej dokładność może zostać znacznie zwiększona. Z tego powodu przeprowadzona została analiza potencjalnych źródeł błędów metody. Jednym z analizowanych czynników bylo pochylenie prowadnicy czujnika pomiarowego, czego dotyczy niniejsza praca.