Identification of dynamic parameters in the context of diagnostics of steel tank with different level of liquid
The paper presents an experimental study to identify the dynamic parameters of a water-filled tank model. The experimental modal analysis approach involving the excitation at one point of the structure and acquisition of vibrations at selected points distributed over the tank surface allowed to determine the resonance frequencies, mode shapes and damping ratios. The main aim of the research was to examine the influence of the level of liquid on the modal parameters. The experimental study showed that the level of water in the tank had an important impact on the values of natural frequencies and damping ratios.
Praca przedstawia badania doświadczalne przeprowadzone w celu identyfikacji parametrów dynamicznych modelu stalowego zbiornika do przechowywania cieczy. Jako techniki badawczej użyto eksperymentalnej analizy modalnej wywołując drgania obciążeniem impulsowym przyłożonym w jednym punkcie konstrukcji i mierząc przyspieszenia drgań w wybranych punktach rozłożonych na powierzchni zbiornika. W badaniach zidentyfikowano częstotliwości drgań własnych, postacie drgań własnych oraz współczynniki tłumienia. Głównym celem pracy była analiza wpływu poziomu cieczy na parametry modalne zbiornika. W pracy wykazano, że stopień napełnienia cieczą znacząco wpływa na częstotliwości drgań własnych oraz współczynniki tłumienia.