Tytuł pozycji:
Development of Resource-Saving Technologies in the Use of Sedimentation Inhibitors for Reverse Osmosis Installations
The processes of desalination of weakly mineralized waters using a reverse osmosis membrane were studied. The operational efficiency of membranes is limited mainly by membrane contamination. It was shown that the preliminary mechanical water purification helps to increase the productivity and selectivity of the membrane. One of the main causes of membrane contamination is the formation of carbonate deposits on their surface. One way to prevent membrane contamination is to dose antiscalants. It was established that the use of hydrolyzed polyacrylonitrile (HPAN) and hydrolyzed polyacrylamide (HPAA) as a stabilizer of scale formation is effective for concentrates of reverse osmosis desalination of water.