Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Development and validation of a stability-indicating UHPLC method for assay of felbamate and related substances

Tytuł:
Development and validation of a stability-indicating UHPLC method for assay of felbamate and related substances
Autorzy:
Shetty, S. K.
Surendranath, K. V.
Kaja, R. K.
Satish, J.
Jogul, J.
Manitripathi, U.
Data publikacji:
2010
Słowa kluczowe:
column liquid chromatography
ultra performance liquid chromatography
felbamate
forced degradation
validation
stability-indicating
Język:
angielski
Dostawca treści:
BazTech
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
A new, sensitive, stability-indicating, and cost and time-effective isocratic reversed-phase UHPLC method has been developed for quantitative analysis of felbamate, an antiepileptic drug, both in the bulk drug and in pharmaceutical dosage forms. Chromatographic separation of felbamate and its two impurities was achieved on a C 18 column with a simple buffer-methanol mobile phase; the run time was 8 min. Quantification was achieved by ultraviolet detection. Resolution between the impurities was >2.0. Response was a linear function of concentration over the range 0.1–3.0 μg mL -1, correlation coefficient >0.999, for felbamate and the impurities. The method is capable of detecting the two impurities at levels of 0.002% (0.02 μg mL -1) of the test concentration of 1.0 mg mL -1 (1 μL injection). The same sensitivity was achieved for all the degradation products formed during stress studies in which the drug was subjected to hydrolysis, oxidation, photolysis, and thermal degradation. Substantial degradation occurred under acidic and basic conditions. The stressed test solutions were assayed against felbamate working standard and the mass balance in each case was close to 100%, indicating the method is stability-indicating. The method was validated for linearity, accuracy, precision, and robustness in accordance with ICH Guidelines.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies