Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Development and validation of a new isocratic RP-HPLC method for simultaneous determination of sodium metabisulfite and sodium benzoate in pharmaceutical formulation

Tytuł:
Development and validation of a new isocratic RP-HPLC method for simultaneous determination of sodium metabisulfite and sodium benzoate in pharmaceutical formulation
Autorzy:
Ivković, B.
Brborić, J.
Dobričić, V.
Čudina, O.
Data publikacji:
2019
Słowa kluczowe:
RP-HPLC
sodium metabisulfite
sodium benzoate
pharmaceutical formulations
Język:
angielski
Dostawca treści:
BazTech
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
A simple and convenient reversed-phase high-performance liquid chromatography (RP-HPLC) method for simultaneous separation, identification, and determination of sodium metabisulfite and sodium benzoate in pharmaceutical formulation has been developed and validated. Chromatographic separation was achieved on RP column Zorbax Extend C-18 (150 × 4.6 mm i.d., 3.5 μm particles), and mixture of 0.1% phosphoric acid and acetonitrile in the ratio 62:38 (v/v) was used as a mobile phase. The flow rate was set at 1.0 mL/min with detection wavelength of 275 nm. The method was successfully validated according to International Conference on Harmonization (ICH) guidelines acceptance criteria. The method is selective, as no interferences were observed at retention times corresponding to these analytes. Results of regression analyses (r) and statistical insignificance of calibration curve intercepts (p) proved linearity of the method in defined concentration ranges for sodium metabisulfite and sodium benzoate (0.05–0.15 mg/mL). Relative standard deviations calculated for both analytes in precision testing were below the limits defined for active pharmaceutical ingredients (analysis repeatability: <2%; intermediate precision: <3%). Recovery values were between 98.16% and 101.94%. According to results of robustness testing, chromatographic parameters are not significantly influenced by small variation of acetonitrile content in mobile phase, column temperature, and flow rate. Finally, the method was applied for quantitative determination of investigated preservatives in real sample analysis.
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2019).

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies