Moisture wall inspection using electrical tomography measurements
This paper presents solutions examining the brick wall dampness using electrical tomography. Different prototype measuring systems based on electrical tomography devices and the laboratory measurement devices were prepared. The prepared constructions contain 16 and 32 electrodes for measuring moisture in the brick wall on one side and two-sided. Electrical tomography, which is based on measuring potential difference, can be used to inspect historical buildings. The way in which we can define state of wall depends on the fact that every material has the unique conductance. To realize this measurement there are necessary electrodes, meters, AC generator, multiplexer and PC with LABview or the tomography device.
W artykule przedstawiono rozwiązania sprawdzające wilgotność murów przy użyciu tomografii elektrycznej. Przygotowano różne prototypowe systemy pomiarowe oparte na elektrycznych urządzeniach tomograficznych oraz systemie laboratoryjnym. Przygotowane konstrukcje zawierają 16 i 32 elektrody do pomiaru zawilgocenia murów z cegły z jednej strony i z obu stron. Do kontroli zabytkowych budynków można wykorzystać tomografię elektryczną, która oparta jest na pomiarze różnicy potencjałów. Sposób, w jaki możemy określić stan murów, zależy od tego, że każdy materiał ma unikalną konduktywność. Do wykonania pomiarów potrzebne są elektrody, mierniki, generatory prądu zmiennego, multiplekser i PC z LABview lub urządzenie tomograficzne.
Opracowanie rekordu w ramach umowy 509/P-DUN/2018 ze środków MNiSW przeznaczonych na działalność upowszechniającą naukę (2018).