Tytuł pozycji:
Efficiency of municipal wastewater treatment with membrane bioreactor
The increasingly stringent requirements for wastewater treatment enforce the adoption of technologies that reduce pollution
and minimize waste production. By combining the typical activated sludge process with membrane filtration, biological
membrane reactors (MBR) offer great technological potential in this respect. The paper presents the principles and effectiveness
of using an MBR at the Głogów Małopolski operation. Physicochemical tests of raw and treated wastewater as
well as microscopic analyses with the use of the FISH (fluorescence in situ hybridization) method were carried out. Moreover,
the level of electric energy consumption during the operation of the wastewater treatment plant and problems related
to fouling were also discussed. A wastewater quality analysis confirmed the high efficiency of removing organic impurities
(on average 96% in case of BOD5 and 94% in case of COD) and suspension (on average 93%).
Wraz ze wzrostem wymagań stawianym ściekom oczyszczonym wdrażane są technologie umożliwiające dużą redukcję
zanieczyszczeń i jednocześnie małą produkcję odpadów. Biologiczne reaktory membranowe (MBR) dzięki połączeniu klasycznego
procesu osadu czynnego z membranową filtracją ścieków stwarzają duże możliwości technologiczne. W pracy
przedstawiono zasadę działania oczyszczalni pracującej w Głogowie Małopolskim oraz efektywność jej działania. Wykonano
analizę fizykochemiczną ścieków surowych i oczyszczonych oraz analizę mikroskopową z wykorzystaniem metody
FISH (fluorescence in situ hybridization), a także przedstawiono poziom zużycia energii elektrycznej podczas pracy
oczyszczalni oraz omówiono problemy związane z zarastaniem membran. Analiza jakości ścieków potwierdziła wysoką
skuteczność usuwania zanieczyszczeń organicznych (średnio 96% w przypadku BZT5 i 94% w przypadku ChZT) oraz zawiesiny
(średnio 93%).