Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

2-Butanone Oxime, a Chemical of Concern in the Working Environment

Tytuł:
2-Butanone Oxime, a Chemical of Concern in the Working Environment
Autorzy:
Dobrzyńska, Elżbieta
Kowalska, Joanna
Data publikacji:
2024
Wydawca:
Polskie Towarzystwo Inżynierii Ekologicznej
Tematy:
butane-2-one oxime
MEKO
working environment
gas chromatography
workplace air
carcinogenic substance
determination method
Źródło:
Journal of Ecological Engineering; 2024, 25, 1; 236-244
2299-8993
Język:
angielski
Prawa:
CC BY: Creative Commons Uznanie autorstwa 4.0
Dostawca treści:
Biblioteka Nauki
Artykuł
  Przejdź do źródła  Link otwiera się w nowym oknie
Employers of the companies where carcinogenic chemicals are being processed or used are obliged to ensure safe working conditions for their employees. Butan-2-one oxime, commonly present in alkyd paints or silicone sealants may pose such a risk due to its reclassification as a category 1B carcinogen. Therefore, in Poland new maximum admissible concentrations (MAC) value of 1 mg/m3 was proposed by interdepartmental Commission for maximum admissible concentrations and intensities for agents harmful to health in the working environment. Assessing exposure to this compound requires a method to be developed for its determination in the workers’ breathing zone, which was the aim of the presented study. A method was developed for determining the aerosol concentrations of 2-butanone oxime in the air at workplaces, in the range of 1/10 to 2 of the MAC value, i.e. from 0.1 mg/m3 to 2 mg/m3. The method involves trapping the airborne aerosol of 2-butanone oxime onto a sampler - a glass tube with silica gel, its extraction with methanol and analysis of the resulting solution using gas chromatography with flame ionization detector in the presence of co-substances. Validation parameters were determined according to the guidelines of EN 482. The limit of detection at 6.79 ng/ml and the relative total uncertainty of 11.19% was determined. The method can be used by environmental occupational hygiene laboratories to measure concentrations of butan-2-one oxime in the air.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies