Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Delayed thrombin generation is associated with minor bleedings in venous thromboembolism patients on rivaroxaban : usefulness of calibrated automated thrombography

Tytuł:
Delayed thrombin generation is associated with minor bleedings in venous thromboembolism patients on rivaroxaban : usefulness of calibrated automated thrombography
Autorzy:
Zalewski, Jarosław
Stępień, Konrad
Undas, Anetta
Caus, Sandi
Butenas, Saulius
Nowak, Karol
Data publikacji:
2020
Słowa kluczowe:
calibrated automated thrombography
minor bleeding
rivaroxaban
venous thromboembolism
vitamin K antagonist
Język:
angielski
Prawa:
Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa
http://creativecommons.org/licenses/by/4.0/legalcode.pl
Linki:
https://www.mdpi.com/2077-0383/9/7/2018  Link otwiera się w nowym oknie
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
leeding is the most feared and difficult to predict adverse event of anticoagulation. We sought to investigate whether calibrated automated thrombography (CAT) parameters are associated with minor bleeding (MB) in anticoagulated patients following venous thromboembolism (VTE). Enrolled were 132 patients on rivaroxaban, 145 on vitamin K antagonists (VKA) and 31 controls who stopped anticoagulation. Prior to the next dose of the anticoagulant, we measured CAT parameters, along with rivaroxaban concentration and INR. During a median follow-up of 10 months, we recorded minor and major bleedings. On rivaroxaban, 27 (20.5%) patients with MB had longer time to start thrombin generation, lower peak thrombin generation and lower endogenous thrombin potential compared with subjects without MB (all p < 0.001). All CAT parameters, except for peak thrombin generation (p = 0.049), were similar in VKA patients with (n = 25, 17.2%) vs. without MBs. By logistic regression, time to start thrombin generation (p = 0.007) and unprovoked VTE (p = 0.041) independently predicted MBs on rivaroxaban. Major bleedings were more frequent in patients with MBs (17.3% vs. 1.8%, p < 0.001). Abnormal CAT parameters characterize VTE patients prone to MBs on rivaroxaban, but not on VKA. Time to start thrombin generation measured about 24 h since the last rivaroxaban dose might help predict MBs.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies