Application of the compress sensing theory for improvement of the TOF resolution in a novel J-PET instrument

Tytuł:
Application of the compress sensing theory for improvement of the TOF resolution in a novel J-PET instrument
Autorzy:
Rudy, Zbigniew
Kapłon, Łukasz
Zoń, Natalia
Bednarski, Tomasz
Gajos, Aleksander
Korcyl, Grzegorz
Zieliński, Marcin
Raczyński, Lech
Krzemień, Wojciech
Kubicz, Ewelina
Kowal, Jakub
Gupta-Sharma, Neha
Czerwiński, Eryk
Niedźwiecki, Szymon
Wieczorek, Anna
Silarski, Michał
Pałka, Marek
Strzelecki, Adam
Kowalski, Paweł
Kochanowski, Andrzej
Salabura, Piotr
Słomski, Artur
Białas, Piotr
Kozik, Tomasz
Moskal, Paweł
Smyrski, Jerzy
Wiślicki, Wojciech
Data publikacji:
2016
Słowa kluczowe:
time of fl ight
compressed sensing
positron emission tomography
Język:
angielski
ISBN, ISSN:
00295922
Prawa:
http://creativecommons.org/licenses/by-nc-nd/3.0/legalcode
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0
Linki:
http://ruj.uj.edu.pl/xmlui/handle/item/29328  Link otwiera się w nowym oknie
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Nowadays, in positron emission tomography (PET) systems, a time of fl ight (TOF) information is used to improve the image reconstruction process. In TOF-PET, fast detectors are able to measure the difference in the arrival time of the two gamma rays, with the precision enabling to shorten signifi cantly a range along the line-of-response (LOR) where the annihilation occurred. In the new concept, called J-PET scanner, gamma rays are detected in plastic scintillators. In a single strip of J-PET system, time values are obtained by probing signals in the amplitude domain. Owing to compressive sensing (CS) theory, information about the shape and amplitude of the signals is recovered. In this paper, we demonstrate that based on the acquired signals parameters, a better signal normalization may be provided in order to improve the TOF resolution. The procedure was tested using large sample of data registered by a dedicated detection setup enabling sampling of signals with 50-ps intervals. Experimental setup provided irradiation of a chosen position in the plastic scintillator strip with annihilation gamma quanta.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies