Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Development of the $^{99m}$Tc-labelled SST$_{2}$ antagonist TECANT-1 for a first-in-man multicentre clinical study

Tytuł:
Development of the $^{99m}$Tc-labelled SST$_{2}$ antagonist TECANT-1 for a first-in-man multicentre clinical study
Autorzy:
Novak, Doroteja
Kolenc Peitl, Petra
Janota, Barbara
Mikołajczak, Renata
Decristoforo, Clemens
Garnuszek, Piotr
Sawicka, Agnieszka
Kroselj, Marko
Hubalewska-Dydejczyk, Alicja
Fani, Melpomeni
Hörmann, Anton Amadeus
Data publikacji:
2023
Słowa kluczowe:
neuroendocrine neoplasms
SPECT
somatostatin receptor antagonists
radiopharmaceuticals
technetium-99m
kit formulation
single dose toxicity
Język:
angielski
ISBN, ISSN:
19994923
Prawa:
http://creativecommons.org/licenses/by/4.0/legalcode.pl
Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa
Linki:
https://www.mdpi.com/1999-4923/15/3/885  Link otwiera się w nowym oknie
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Broad availability and cost-effectiveness of $^{99}$Mo/$^{99m}$Tc generators worldwide support the use, and thus the development, of novel $^{99m}$Tc-labelled radiopharmaceuticals. In recent years, preclinical and clinical developments for neuroendocrine neoplasms patient management focused on somatostatin receptor subtype 2 (SST2) antagonists, mainly due to their superiority in SST2-tumour targeting and improved diagnostic sensitivity over agonists. The goal of this work was to provide a reliable method for facile preparation of a $^{99m}$Tc-labelled SST2 antagonist, [$^{99m}$Tc]Tc-TECANT-1, in a hospital radiopharmacy setting, suitable for a multi-centre clinical trial. To ensure successful and reproducible on-site preparation of the radiopharmaceutical for human use shortly before administration, a freeze-dried three-vial kit was developed. The final composition of the kit was established based on the radiolabelling results obtained during the optimisation process, in which variables such as precursor content, pH and buffer, as well as kit formulations, were tested. Finally, the prepared GMP-grade batches met all predefined specification parameters together with long-term kit stability and stability of the product [$^{99m}$Tc]Tc-TECANT-1. Furthermore, the selected precursor content complies with micro-dosing, based on an extended single-dose toxicity study, where histopathology NOEL was established at 0.5 mg/kg BW, being more than 1000 times higher than the planned human dose of 20 µg. In conclusion, [$^{99}$Tc]Tc-TECANT-1 is suitable to be advanced into a first-in-human clinical trial.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies