Hemodynamic parameters of aortic valve prostheses – KRAK-AS registry analysis

Tytuł:
Hemodynamic parameters of aortic valve prostheses – KRAK-AS registry analysis
Autorzy:
Golińska-Grzybała, Karolina
Frączek-Jucha, Magdalena
Nessler, Jadwiga
Sorysz, Danuta
Stąpór, Maciej
Gackowski, Andrzej
Pińska, Małgorzata
Data publikacji:
2023
Słowa kluczowe:
aortic valve
prosthesis failure
aortic stenosis
echocardiography
Język:
angielski
ISBN, ISSN:
17349338
Prawa:
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Na tych samych warunkach 4.0 Międzynarodowa
Linki:
http://dx.doi.org/10.5114/aic.2023.129214  Link otwiera się w nowym oknie
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Introduction: The treatment of choice for aortic stenosis is a valve replacement. Some patients have post-procedural increased pressure gradient on the implanted prosthesis because of patient-prosthesis mismatch (PPM), known to adversely influence prognosis. The PPM risk should be initially predicted and effort made to avoid this complication, specifically in large body size patients. Aim: To assess the frequency of PPM taking into account the valvular prosthesis type in a real-life population of consecutive patients included in the Krakow aortic stenosis registry. Material and methods: The KRAK-AS registry was conducted in July-October 2016. Patients were assessed before and after valve surgery and during the 3-year follow-up. Patients who underwent aortic valve intervention were clinically and echocardiographically evaluated within a month after surgery and divided into groups depending on the implanted prosthesis type. Analysis of patients with a smaller (< 23 mm) and larger than median (≥ 23 mm) valve diameter was performed. Results: The valve implantation was performed in 229 patients (42 mechanical, 139 biological, 48 transcatheter). No differences between patient groups compared by PPM occurrence was seen at baseline. Median age was 70 years; 55.5% were men. At least moderate PPM (iEOA ≤ 0.85 cm2/m2) was observed in 40% of mechanical valves, 33% of biological valves, and was significantly less frequent (10%) in patients after transcatheter valve implantation, p = 0.0001. Severe PPM (iEOA < 0.65 cm2/m2) was found in 17.6% of mechanical valve PPM patients, 4.3% of biological ones, and no patients after transcatheter procedure. Conclusions: PPM is a frequent phenomenon in the real-life population of patients undergoing surgical aortic valve replacement, being significantly less frequent in the case of a transcatheter procedure.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies