Tytuł pozycji:

Comparison of image quality, diagnostic accuracy and radiation dose between flash model and retrospective ECG-triggered protocols in dual source computed tomography (DSCT) in congenital heart diseases

Tytuł:
Comparison of image quality, diagnostic accuracy and radiation dose between flash model and retrospective ECG-triggered protocols in dual source computed tomography (DSCT) in congenital heart diseases
Autorzy:
Xu, Xiang-Jiu
Wang, Rong
Zhang, Wen-Wen
Huang, Gang
Zuo, Xiao-na
Zhou, Xing
Ma, Ya-Qiong
Data publikacji:
2017
Słowa kluczowe:
multidetector computed tomography
radiation dosage
jervell-lange nielsen syndrome
image enhancement
Język:
angielski
ISBN, ISSN:
1733134X
Prawa:
http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska
Linki:
http://ruj.uj.edu.pl/xmlui/handle/item/39002  Link otwiera się w nowym oknie
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
BACKGROUND: Dual source computed tomography (DSCT) plays an important role in the diagnosis of congenital heart diseases (CHD). However, the issue of radiation-related side effects constitutes a wide public concern. The aim of the study was to explore the differences in diagnostic accuracy, radiation dose and image quality between a prospectively ECG - triggered high - pitch spiral acquisition (flash model) and a retrospective ECG-gated protocol of DSCT used for the detection of CHD. MATERIAL AND METHODS: The study included 58 patients with CHD who underwent a DSCT examination, including two groups of 29 patients in each protocol. Then, both subjective and objective image quality, diagnostic accuracy and radiation dose were compared between the two protocols. RESULTS: The image quality and the total as well as partial diagnostic accuracy did not differ significantly between the protocols. The radiation dose in the flash model was obviously lower than that in the retrospective model (P<0.05). CONCLUSIONS: Compared to the retrospective protocol, the flash model can significantly reduce the dose of radiation, while maintaining both diagnostic accuracy and image quality.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies