Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Triaxial system in re-embolization for recanalization of pulmonary arteriovenous malformations

Tytuł:
Triaxial system in re-embolization for recanalization of pulmonary arteriovenous malformations
Autorzy:
Ohta, Kengo
Hashizume, Takuya
Shimohira, Masashi
Kawai, Tatsuya
Suzuki, Kazushi
Muto, Masahiro
Shibamoto, Yuta
Data publikacji:
2015
Słowa kluczowe:
embolization
therapeutic
pulmonary artery
catheterization
Język:
angielski
ISBN, ISSN:
1733134X
Prawa:
http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska
Linki:
http://ruj.uj.edu.pl/xmlui/handle/item/42448  Link otwiera się w nowym oknie
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Background: Recanalization occurs occasionally, following coil embolization of pulmonary arteriovenous malformations (PAVM), and can lead to ischemic stroke; therefore re-embolization is important. A 1.9-Fr. no-taper microcatheter that can be inserted into a 2.7-Fr. microcatheter (named the triaxial system) has recently become available, and contributes to super-selective catheterization for small or tortuous vessels. The aim of this study was to evaluate the usefulness of re-embolization for recanalization of PAVM using the triaxial system. Material and Methods: Recanalization was diagnosed in 8 patients with 13 PAVMs between June 2011 and November 2012, and re-embolization was attempted with a conventional microcatheter at first in all 13 PAVMs. However, in three of them it failed with the conventional microcatheter, and then the system was exchanged to the triaxial system. Thus, re-embolization using the triaxial system was performed in 3 PAVMs of 3 female patients, with a median age of 63 years (range, 46–73 years). We assessed technical success, complications, and outcome. Results: The disappearance of recanalization was confirmed by angiography in all re-embolization procedures (technical success rate was 100%). Re-embolization was then successfully achieved inside the original coils, and no branch artery of normal lung tissue was embolized. There were no complications related with this procedure. The blood flow of recanalization was decreased in all cases in a follow-up of 27-33 months (median, 31). Conclusions: Triaxial system appears to be useful for recanalization of PAVM, especially in difficult cases with a conventional system.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies