Informacja

Drogi użytkowniku, aplikacja do prawidłowego działania wymaga obsługi JavaScript. Proszę włącz obsługę JavaScript w Twojej przeglądarce.

Tytuł pozycji:

Intraarterial CT angiography using ultra low volume of iodine contrast : own experiences

Tytuł:
Intraarterial CT angiography using ultra low volume of iodine contrast : own experiences
Autorzy:
Garcarek, Jerzy
Miś, Marcin
Gołębiowski, Tomasz
Banasik, Mirosław
Kurcz, Jacek
Guziński, Maciej
Data publikacji:
2015
Słowa kluczowe:
gastrointestinal hemorrhage
multidetector computed tomography
digital subtraction
infusions
kidney transplantation
angiography
intra-arterial
contrast media
Język:
angielski
ISBN, ISSN:
1733134X
Prawa:
http://creativecommons.org/licenses/by-nc-nd/3.0/pl/legalcode
Udzielam licencji. Uznanie autorstwa - Użycie niekomercyjne - Bez utworów zależnych 3.0 Polska
Linki:
http://ruj.uj.edu.pl/xmlui/handle/item/42832  Link otwiera się w nowym oknie
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
BACKGROUND: High volume of intravenous contrast in CT-angiography may result in contrast-induced nephropathy. Intraarterial ultra-low volume of contrast medium results in its satisfactory blood concentration with potentially good image quality. The first main purpose was to assess the influence of the method on function of transplanted kidney in patients with impaired graft function. The second main purpose of the study was to evaluate the usefulness of this method for detection of gastrointestinal and head-and-neck haemorrhages. MATERIAL AND METHODS: Between 2010 and 2013 intraarterial CT-angiography was performed in 56 patients, including 28 with chronic kidney disease (CKD). There were three main subgroups: 18 patients after kidney transplantation, 10 patients with gastrointestinal hemorrhage, 8 patients with head-and-neck hemorrhage. Contralateral or ipsilateral inguinal arterial approach was performed. The 4-French vascular sheaths and 4F-catheters were introduced under fluoroscopy. Intraarterial CT was performed using 64-slice scanner. The scanning protocol was as follows: slice thickness 0.625 mm, pitch 1.3, gantry rotation 0.6 sec., scanning delay 1-2 sec. The extent of the study was established on the basis of scout image. In patients with CKD 6-8 mL of Iodixanol (320 mg/mL) diluted with saline to 18-24 mL was administered at a speed of 4-5 mL/s. RESULTS: Vasculature was properly visualized in all patients. In patients with impaired renal function creatinine/eGFR levels remained stable in all but one case. Traditional arteriography failed and CT-angiography demonstrated the site of bleeding in 3 of 10 patients with symptoms of gastrointestinal bleeding (30%). In 8 patients with head-and-neck bleeding CT-angiography did not prove beneficial when compared to traditional arteriography. CONCLUSIONS: 1. Ultra-low contrast intraarterial CT-angiography does not deteriorate the function of transplanted kidneys in patients with impaired graft function. 2. 3D reconstructions allow for excellent visualization of vascular anatomy of renal transplants. 3. Intraarterial CT-angiography is useful for detection of the bleeding site.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies