Reliability study of weight-bearing upper extremity sway test performed on a force plate in the one-handed plank position

Tytuł:
Reliability study of weight-bearing upper extremity sway test performed on a force plate in the one-handed plank position
Autorzy:
Sopa, Martyna
Zyznawska, Joanna
Dzięcioł-Anikiej, Zofia
Bril, Grzegorz
Adamska, Olga
Oleksy, Łukasz
Kielnar, Renata
Deszczyński, Jarosław Michał
Stolarczyk, Artur
Mika, Anna
Witkowski, Jarosław
Kuchciak, Maciej
Data publikacji:
2024
Słowa kluczowe:
sway test
reliability
plank position
upper limb
stabilometry
platform
Język:
angielski
ISBN, ISSN:
20763417
Prawa:
Udzielam licencji. Uznanie autorstwa 4.0 Międzynarodowa
http://creativecommons.org/licenses/by/4.0/legalcode.pl
Linki:
https://www.mdpi.com/2076-3417/14/24/11945  Link otwiera się w nowym oknie
Dostawca treści:
Repozytorium Uniwersytetu Jagiellońskiego
Artykuł
Background: The aim of this study is to determine the intra-rater and test–retest reliability of an upper extremity sway test performed in the one-handed plank position on a force plate and to establish if there are any between-limb differences in assessment with either open or closed eyes. (2) Methods: Fifteen males participated in this study (23.1 ± 2.3 years; 71.2 ± 7.4 kg; 175 ± 4 cm). The sway test (ST) on the force plate was performed during two separate visits, with a one-week interval between tests performed with eyes open and closed, separately for the left and right upper limbs. (3) Results: Intra-rater reliability for measurements with eyes open and closed on both the left and right sides was good to excellent for almost all variables (ICC = 0.84–0.96). Moderate reliability was observed only for the center of pressure (COP) area. Test–retest reliability was somewhat lower. With eyes open and closed, good to excellent reliability was observed for COP length and velocity in the M-L direction and for the total COP length (ICC = 0.77–0.95). However, for COP length and velocity in the A-P direction, as well as for COP area, reliability was moderate (ICC = 0.58–0.70). No significant differences were found between the left and right sides in any variable. (4) Conclusions: The results of this study indicate that the upper limb sway test performed on a force plate in the one-handed plank position, both with eyes open and closed, is a reliable measurement option and has practical applications in clinical settings, including for baseline assessments, return-to-play protocols, and injury prevention strategies.

Ta witryna wykorzystuje pliki cookies do przechowywania informacji na Twoim komputerze. Pliki cookies stosujemy w celu świadczenia usług na najwyższym poziomie, w tym w sposób dostosowany do indywidualnych potrzeb. Korzystanie z witryny bez zmiany ustawień dotyczących cookies oznacza, że będą one zamieszczane w Twoim komputerze. W każdym momencie możesz dokonać zmiany ustawień dotyczących cookies